Transmittance of spectrum by several profile sheet

We tested the transmittance of spectrum by several profile sheet with 12 different PC Hollow Profile Sheets.

graph_several_profiles_sheet

– Light Blue Hollow profile sheet: Keep the sunlight and intensity for each light range as following: blue light 400NM~500NM(70%), Green light 500NM~600NM(55%) Red light 600NM~700NM(20%)

– Greenish Blue Hollow profile sheet: Keep the sunlight and intensity for each light range as following: blue light 400NM~500NM(60%) Green light 500NM~600NM(50%) Red light 600NM~700NM(15%)

– Blue Hollow profile sheet: Keep the sunlight and intensity for each light range as following: blue light 400NM~500NM(45% Green light 500NM~600NM(25%) Red light 600NM~700NM(5%)

– Green Hollow profile sheet: Keep the sunlight and intensity for each light range as following: blue light 400NM~500NM(42%) Green light 500NM~600NM(50%) Red light 600NM~700NM(15%)

– Grey Hollow profile sheet: Keep the sunlight and intensity for each light range as following: blue light 400NM~500NM(25%) Green light 500NM~600NM(20%) Red light 600NM~700NM(30%)

– Opal Hollow profile sheet: Keep the sunlight and intensity for each light range as following: blue light 400NM~500NM(25%) Green light 500NM~600NM(20%) Red light 600NM~700NM(30%)

– Red Hollow profile sheet: Keep the sunlight and intensity for each light range as following: blue light 400NM~500NM(5%) Green light 500NM~600NM(10%) Red light 600NM~700NM(70%)

– Pink Hollow profile sheet: Keep the sunlight and intensity for each light range as following: blue light 400NM~500NM(48%) Green light 500NM~600NM(50%) Red light 600NM~700NM(75%)

– Yellow Hollow profile sheet: Keep the sunlight and intensity for each light range as following: blue light 400NM~500NM(5%) Green light 500NM~600NM(70%) Red light 600NM~700NM(78%)

– Orange Hollow profile sheet: Keep the sunlight and intensity for each light range as following: blue light 400NM~500NM(0%) Green light 500NM~600NM(20%) Red light 600NM~700NM(68%)

– Bronze Hollow profile sheet: Keep the sunlight and intensity for each light range as following: blue light 400NM~500NM(38%) Green light 500NM~600NM(35%) Red light 600NM~700NM(42%)

– Clear Hollow profile sheet: Keep the sunlight and intensity for each light range as following: blue light 400NM~500NM(80%) Green light 500NM~600NM(80%) Red light 600NM~700NM(80%)

– Above 12 type of Hollow profile sheets, the Pink Hollow Profile sheet keep the highest ratio of red light spectrum and intensity for the plant.

– Clear Hollow profile sheet keep 80% for spectrum and intensity will be too much.